The firmware update is a sensitive procedure
By using this software, you agree to take full responsibility. TripLogik will not be responsible for any loss, or damage or password corruption. 
we have done thousands of updates, and the only circumstance your password will be corrupted, is if procedure is not followed.
TripLogik WILL CHARGE YOU A FEE IF YOU DID NOT FOLLOW THE PROCEDURE, TO FIX YOUR INSTRUMENT. DATA WILL NOT BE RETRIEVABLE. 
If you do not agree, please do not update your firmware.
 

Why this update of firmware.:  Leap year date error on Feb 29 

The TL1000 Firmware was updated in order to fix a bug that only happens in leap years
Report will show a wrong date assigned to trips recorded on the 29th of Feb.

Without this update, all trips made on Fed 29 will be marked as made on the 28th .
This bug does not change anything to the total mileage in the report, it only shows a wrong date.


IMPORTANT NOTES

Please make a complete Sync of your instrument before any update.

Ensure you have made a backup of your data file on an external hard drive, USB key etc.


** If the current version, you are using is 1.24 or older and you have a password set in the device.

DO NOT PROCEED IF YOU HAVE A PASSWORD IN THE INSTRUMENT OR IT WILL DAMAGE THE PASSWORD AND WILL PREVENT YOU FROM RETRIEVING ANY DATA.


You MUST change the password of your INSTRUMENT so it is the same as the  serial number ( 16 CHARACTER LONG  TL1000010XXXXXXX )

Serial number is WRITTEN UNDER THE INSTRUMENT

If you can't find the serial number, please use the SN utility here http://www.triplogik.com/download/GetTLDeviceInfo.exe


WARNING  

Changing the password will ERASE ALL DATA from the device and it can't be restored 

Once the update is done, you will have to change it back to the password you were using ( to ensure it will work with your current database)

VERIFY your instrument works with a proper password BEFORE installing it in your car.

If the password is corrupted, any data recorded after this change will not be readable! 



Firmware download link  TL1000 1.25 Firmware


  1. Close all other applications
  2. Make sure you have changed the password as described above if it applies
  3. Open the firmware updater 1.25
  4. Connect the TL1000
  5. When the TL is detected, you can see the version already installed
  6. Click "install" to start the update
  7. When completed, close the software and unplug the TL1000
  8. Open the Manager 2.0 and connect the instrument to your PC to check that the password is still working




By using this software, you agree to take full responsibility. 